University of Surrey

Test tubes in the lab Research in the ATI Dance Research

Items where Author is "McLaughlin, R"

Up a level
Export as [feed] RSS 1.0 [feed] RSS 2.0
Group by: Item Type | No Grouping
Number of items: 77.

Article

Li, Jiawen, Fejes, Peter, Lorenser, Dirk, Quirk, Bryden C., Noble, Peter B., Kirk, Rodney W., Orth, Antony, Wood, Fiona M., Gibson, Brant C., Sampson, David D. and McLaughlin, Robert A. (2018) Two-photon polymerisation 3D printed freeform micro-optics for optical coherence tomography fibre probes Scientific Reports, 8 (1), 14789. pp. 1-9.

Li, J., Quirk, B.C., Noble, P.B., Kirk, R.W., Sampson, David and McLaughlin, R.A. (2017) Flexible needle with integrated optical coherence tomography probe for imaging during transbronchial tissue aspiration Journal of Biomedical Optics, 22 (10).

Es’haghian, S., Kennedy, K.M., Gong, P., Li, Q., Chin, L., Wijesinghe, P., Sampson, David, McLaughlin, R.A. and Kennedy, B.F. (2017) In vivo volumetric quantitative microelastography of human skin Biomedical Optics Express, 8 (5). pp. 2458-2471.

Es'haghian, S., Gong, P., Chin, L., Harms, K.-A., Murray, A., Rea, S., Kennedy, B.F., Wood, F.M., Sampson, David and McLaughlin, R.A. (2017) Investigation of optical attenuation imaging using optical coherence tomography for monitoring of scars undergoing fractional laser treatment Journal of Biophotonics, 10 (4). pp. 511-522.

Villiger, M., Lorenser, D., McLaughlin, R.A., Quirk, B.C., Kirk, R.W., Bouma, B.E. and Sampson, David (2016) Deep tissue volume imaging of birefringence through fibre-optic needle probes for the delineation of breast tumour Scientific Reports, 6.

Gong, P., Es'haghian, S., Harms, K.-A., Murray, A., Rea, S., Wood, F.M., Sampson, David and McLaughlin, R.A. (2016) In vivo label-free lymphangiography of cutaneous lymphatic vessels in human burn scars using optical coherence tomography Biomedical Optics Express, 7 (12). pp. 4886-4898.

Kennedy, K.M., Chin, L., Wijesinghe, P., McLaughlin, R.A., Latham, B., Sampson, David, Saunders, C.M. and Kennedy, B.F. (2016) Investigation of optical coherence micro-elastography as a method to visualize micro-architecture in human axillary lymph nodes BMC Cancer, 16 (1).

Gong, P., Es'haghian, S., Wood, F.M., Sampson, David and McLaughlin, R.A. (2016) Optical coherence tomography angiography for longitudinal monitoring of vascular changes in human cutaneous burns Experimental Dermatology, 25 (9). pp. 722-724.

Ansell, T.K., McFawn, P.K., McLaughlin, R.A., Sampson, David, Eastwood, P.R., Hillman, D.R., Mitchell, H.W. and Noble, P.B. (2015) Does smooth muscle in an intact airway undergo length adaptation during a sustained change in transmural pressure? Journal of Applied Physiology, 118 (5). pp. 533-543.

Kennedy, B.F., McLaughlin, R.A., Kennedy, K.M., Chin, L., Wijesinghe, P., Curatolo, A., Tien, A., Ronald, M., Latham, B., Saunders, C.M. and Sampson, David (2015) Investigation of optical coherence microelastography as a method to visualize cancers in human breast tissue Cancer Research, 75 (16). pp. 3236-3245.

Scolaro, L., Lorenser, D., Madore, W.-J., Kirk, R.W., Kramer, A.S., Yeoh, G.C., Godbout, N., Sampson, David, Boudoux, C. and McLaughlin, R.A. (2015) Molecular imaging needles: Dual-modality optical coherence tomography and fluorescence imaging of labeled antibodies deep in tissue Biomedical Optics Express, 6 (5). pp. 1767-1781.

Kirk, R.W., Kennedy, B.F., Sampson, David and McLaughlin, R.A. (2015) Near Video-Rate Optical Coherence Elastography by Acceleration With a Graphics Processing Unit Journal of Lightwave Technology, 33 (16). pp. 3481-3485.

Es'Haghian, S., Kennedy, K.M., Gong, P., Sampson, David, McLaughlin, R.A. and Kennedy, B.F. (2015) Optical palpation in vivo: Imaging human skin lesions using mechanical contrast Journal of Biomedical Optics, 20 (1).

Wijesinghe, P., McLaughlin, R.A., Sampson, David and Kennedy, B.F. (2015) Parametric imaging of viscoelasticity using optical coherence elastography Physics in Medicine and Biology, 60 (6). pp. 2293-2307.

Kennedy, K.M., Chin, L., McLaughlin, R.A., Latham, B., Saunders, C.M., Sampson, David and Kennedy, B.F. (2015) Quantitative micro-elastography: Imaging of tissue elasticity using compression optical coherence elastography Scientific Reports, 5.

Chin, L., Curatolo, A., Kennedy, B.F., Doyle, B.J., Munro, P.R.T., McLaughlin, R.A. and Sampson, David (2014) Analysis of image formation in optical coherence elastography using a multiphysics approach Biomedical Optics Express, 5 (9). pp. 2913-2930.

Gong, P., McLaughlin, R.A., Liew, Y.M., Munro, P.R.T., Wood, F.M. and Sampson, David (2014) Assessment of human burn scars with optical coherence tomography by imaging the attenuation coefficient of tissue after vascular masking Journal of Biomedical Optics, 19 (2).

Yang, X., Lorenser, D., McLaughlin, R.A., Kirk, R.W., Edmond, M., Simpson Cather, M., Grounds, M.D. and Sampson, David (2014) Imaging deep skeletal muscle structure using a high-sensitivity ultrathin side-viewing optical coherence tomography needle probe Biomedical Optics Express, 5 (1). pp. 136-148.

Gong, P., Chin, L., Es'Haghian, S., Liew, Y.M., Wood, F.M., Sampson, David and McLaughlin, R.A. (2014) Imaging of skin birefringence for human scar assessment using polarization-sensitive optical coherence tomography aided by vascular masking Journal of Biomedical Optics, 19 (12).

McLaughlin, R.A., Noble, P.B. and Sampson, David (2014) Optical coherence tomography in respiratory science and medicine: From airways to alveoli Physiology, 29 (5). pp. 369-380.

Kennedy, K.M., Es'haghian, S., Chin, L., McLaughlin, R.A., Sampson, David and Kennedy, B.F. (2014) Optical palpation: Optical coherence tomography-based tactile imaging using a compliant sensor Optics Letters, 39 (10). pp. 3014-3017.

Quirk, B.C., McLaughlin, R.A., Pagnozzi, A.M., Kennedy, B.F., Noble, P.B. and Sampson, David (2014) Optofluidic needle probe integrating targeted delivery of fluid with optical coherence tomography imaging Optics Letters, 39 (10). pp. 2888-2891.

Chin, L., Kennedy, B.F., Kennedy, K.M., Wijesinghe, P., Pinniger, G.J., Terrill, J.R., McLaughlin, R.A. and Sampson, David (2014) Three-dimensional optical coherence microelastography of skeletal muscle tissue Biomedical Optics Express, 5 (9). pp. 3090-3102.

Kennedy, B.F., Chin, L., Kennedy, K.M., Wijesinghe, P., Curatolo, A., Es'haghian, S., Munro, P.R.T., McLaughlin, R.A. and Sampson, David (2014) A new window into disease Optics and Photonics News, 25 (12).

Scolaro, L., McLaughlin, R.A., Kennedy, B.F., Saunders, C.M. and Sampson, David (2014) A review of optical coherence tomography in breast cancer Photonics and Lasers in Medicine, 3 (3). pp. 225-240.

Pagnozzi, A.M., Kirk, R.W., Kennedy, B.F., Sampson, David and McLaughlin, R.A. (2013) Automated quantification of lung structures from optical coherence tomography images Biomedical Optics Express, 4 (11). pp. 2383-2395.

Lorenser, D., Quirk, B.C., Auger, M., Madore, W.-J., Kirk, R.W., Godbout, N., Sampson, David, Boudoux, C. and McLaughlin, R.A. (2013) Dual-modality needle probe for combined fluorescence imaging and three-dimensional optical coherence tomography Optics Letters, 38 (3). pp. 266-268.

Chin, L., Yang, X., McLaughlin, R.A., Noble, P.B. and Sampson, David (2013) En face parametric imaging of tissue birefringence using polarization-sensitive optical coherence tomography Journal of Biomedical Optics, 18 (6).

Liew, Y.M., McLaughlin, R.A., Gong, P., Wood, F.M. and Sampson, David (2013) Erratum: In vivo assessment of human burn scars through automated quantification of vascularity using optical coherence tomography (Journal of Biomedical Optics (2013) 18 (061213)) Journal of Biomedical Optics, 18 (6).

Liew, Y.M., McLaughlin, R.A., Gong, P., Wood, F.M. and Sampson, David (2013) In vivo assessment of human burn scars through automated quantification of vascularity using optical coherence tomography Journal of Biomedical Optics, 18 (6).

Kennedy, K.M., McLaughlin, R.A., Kennedy, B.F., Tien, A., Latham, B., Saunders, C.M. and Sampson, David (2013) Needle optical coherence elastography for the measurement of microscale mechanical contrast deep within human breast tissues Journal of Biomedical Optics, 18 (12).

Yang, X., Chin, L., Klyen, B.R., Shavlakadze, T., McLaughlin, R.A., Grounds, M.D. and Sampson, David (2013) Quantitative assessment of muscle damage in the mdx mouse model of Duchenne muscular dystrophy using polarization-sensitive optical coherence tomography Journal of Applied Physiology, 115 (9). pp. 1393-1401.

Yeo, B.Y., McLaughlin, R.A., Kirk, R.W. and Sampson, D.D. (2012) Enabling freehand lateral scanning of optical coherence tomography needle probes with a magnetic tracking system Biomedical Optics Express, 3 (7). pp. 1565-1578.

Scolaro, L., Lorenser, D., McLaughlin, R.A., Quirk, B.C., Kirk, R.W. and Sampson, D.D. (2012) High-sensitivity anastigmatic imaging needle for optical coherence tomography Optics Letters, 37 (24). pp. 5247-5249.

McLaughlin, R.A., Quirk, B.C., Curatolo, A., Kirk, R.W., Scolaro, L., Lorenser, D., Robbins, P.D., Wood, B.A., Saunders, C.M. and Sampson, D.D. (2012) Imaging of breast cancer with optical coherence tomography needle probes: Feasibility and initial results IEEE Journal on Selected Topics in Quantum Electronics, 18 (3). pp. 1184-1191.

Liew, Y.M., McLaughlin, R.A., Wood, F.M. and Sampson, D.D. (2012) Motion correction of in vivo three-dimensional optical coherence tomography of human skin using a fiducial marker Biomedical Optics Express, 3 (8). pp. 1774-1786.

Kennedy, K.M., Kennedy, B.F., McLaughlin, R.A. and Sampson, D.D. (2012) Needle optical coherence elastography for tissue boundary detection Optics Letters, 37 (12). pp. 2310-2312.

Scolaro, L., McLaughlin, R.A., Klyen, B.R., Wood, B.A., Robbins, P.D., Saunders, C.M., Jacques, S.L. and Sampson, D.D. (2012) Parametric imaging of the local attenuation coefficient in human axillary lymph nodes assessed using optical coherence tomography Biomedical Optics Express, 3 (2). pp. 366-379.

McLaughlin, R.A., Yang, X., Quirk, B.C., Lorenser, D., Kirk, R.W., Noble, P.B. and Sampson, D.D. (2012) Static and dynamic imaging of alveoli using optical coherence tomography needle probes Journal of Applied Physiology, 113 (6). pp. 967-974.

Kennedy, B.F., Koh, S.H., McLaughlin, R.A., Kennedy, K.M., Munro, P.R.T. and Sampson, D.D. (2012) Strain estimation in phase-sensitive optical coherence elastography Biomedical Optics Express, 3 (8). pp. 1865-1879.

Curatolo, A., McLaughlin, R.A., Quirk, B.C., Kirk, R.W., Bourke, A.G., Wood, B.A., Robbins, P.D., Saunders, C.M. and Sampson, D. D. (2012) Ultrasound-guided optical coherence tomography needle probe for the assessment of breast cancer tumor margins American Journal of Roentgenology, 199 (4). W520-W522.

Williamson, J.P., McLaughlin, R.A., Noffsinger, W.J., James, A.L., Baker, V.A., Curatolo, A., Armstrong, J.J., Regli, A., Shepherd, K.L., Marks, G.B., Sampson, D.D., Hillman, D.R. and Eastwood, P.R. (2011) Elastic properties of the central airways in obstructive lung diseases measured using anatomical optical coherence tomography American Journal of Respiratory and Critical Care Medicine, 183 (5). pp. 612-619.

Quirk, B.C., McLaughlin, R.A., Curatolo, A., Kirk, R.W., Noble, P.B. and Sampson, D.D. (2011) In situ imaging of lung alveoli with an optical coherence tomography needle probe Journal of Biomedical Optics, 16 (3).

Liew, Y.M., McLaughlin, R.A., Wood, F.M. and Sampson, D.D. (2011) Reduction of image artifacts in three-dimensional optical coherence tomography of skin in vivo Journal of Biomedical Optics, 16 (11).

Lorenser, D., Yang, X., Kirk, R.W., Quirk, B.C., McLaughlin, R.A. and Sampson, D.D. (2011) Ultrathin side-viewing needle probe for optical coherence tomography Optics Letters, 36 (19). pp. 3894-3896.

Noble, P.B., West, A.R., McLaughlin, R.A., Armstrong, J.J., Becker, S., McFawn, P.K., Williamson, J.P., Eastwood, P.R., Hillman, D.R., Sampson, D.D. and Mitchell, H.W. (2010) Airway narrowing assessed by anatomical optical coherence tomography in vitro: Dynamic airway wall morphology and function Journal of Applied Physiology, 108 (2). pp. 401-411.

McLaughlin, R.A. and Sampson, D.D. (2010) Clinical applications of fiber-optic probes in optical coherence tomography Optical Fiber Technology, 16 (6). pp. 467-475.

Noble, P.B., McLaughlin, R.A., West, A.R., Becker, S., Armstrong, J.J., McFawn, P.K., Eastwood, P.R., Hillman, D.R., Sampson, D.D. and Mitchell, H.W. (2010) Distribution of airway narrowing responses across generations and at branching points, assessed in vitro by anatomical optical coherence tomography Respiratory Research, 11.

Williamson, J.P., McLaughlin, R.A., Phillips, M.J., Curatolo, A., Armstrong, J.J., Maddison, K.J., Sheehan, R.E., Sampson, D.D., Hillman, D.R. and Eastwood, P.R. (2010) Feasibility of applying real-time optical imaging during bronchoscopic interventions for central airway obstruction Journal of Bronchology and Interventional Pulmonology, 17 (4). pp. 307-316.

McLaughlin, R.A., Scolaro, L., Robbins, P., Hamza, S., Saunders, C. and Sampson, D.D. (2010) Imaging of human lymph nodes using optical coherence tomography: potential for staging cancer Cancer Research, 70 (7). pp. 2579-2584.

Lau, B., McLaughlin, R.A., Curatolo, A., Kirk, R.W., Gerstmann, D.K. and Sampson, D.D. (2010) Imaging true 3D endoscopic anatomy by incorporating magnetic tracking with optical coherence tomography: Proof-of-principle for airways Optics Express, 18 (26). pp. 27173-27180.

Williamson, J.P., Armstrong, J.J., McLaughlin, R.A., Noble, P.B., West, A.R., Becker, S., Curatolo, A., Noffsinger, W.J., Mitchell, H.W., Phillips, M.J., Sampson, D.D., Hillman, D.R. and Eastwood, P.R. (2010) Measuring airway dimensions during bronchoscopy using anatomical optical coherence tomography European Respiratory Journal, 35 (1). pp. 34-41.

McLaughlin, R.A., Scolaro, L., Robbins, P., Saunders, C., Jacques, S.L. and Sampson, D.D. (2010) Parametric imaging of cancer with optical coherence tomography Journal of Biomedical Optics, 15 (4).

Kennedy, B.F., Hillman, T.R., McLaughlin, R.A., Quirk, B.C. and Sampson, David (2009) In vivo dynamic optical coherence elastography using a ring actuator Optics Express, 17 (24). pp. 21762-21772.

McLaughlin, R.A., Scolaro, L., Robbins, P., Saunders, C., Jacques, S.L. and Sampson, David (2009) Mapping tissue optical attenuation to identify cancer using optical coherence tomography. Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention, 12 (Pt 2). pp. 657-664.

Williamson, J.P., McLaughlin, R.A., Phillips, M.J., Armstrong, J.J., Becker, S., Walsh, J.H., Sampson, David, Hillman, D.R. and Eastwood, P.R. (2009) Using optical coherence tomography to improve diagnostic and therapeutic bronchoscopy Chest, 136 (1). pp. 272-276.

McLaughlin, R.A., Williamson, J.P., Phillips, M.J., Armstrong, J.J., Becker, S., Hillman, D.R., Eastwood, P.R. and Sampson, David (2008) Applying anatomical optical coherence tomography to quantitative 3D imaging of the lower airway Optics Express, 16 (22). pp. 17521-17529.

Book Section

McLaughlin, R.A., Lorenser, D. and Sampson, David (2013) Needle probes in optical coherence tomography In: Handbook of Coherent-Domain Optical Methods: Biomedical Diagnostics, Environmental Monitoring, and Materials Science:: Second Edition. Springer New York, pp. 1065-1102.

Conference or Workshop Item

Gong, P., Es'haghian, S., Harms, K.-A., Murray, A., Rea, S., Wood, F.M., Sampson, David and McLaughlin, R.A. (2017) Extracting something from nothing: In vivo imaging of human cutaneous lymphatic vessels using optical coherence tomography

Phan, A., Karnowski, K., Lee, Q., Fejes, P., Quirk, B., McLaughlin, R., Wood, F.M. and Sampson, David (2017) Preliminary results on in-vivo imaging of upper airway inhalation injuries using anatomical optical coherence tomography

Es'haghian, S., Gong, P., Kennedy, K.M., Wijesinghe, P., Sampson, David, McLaughlin, R.A. and Kennedy, B.F. (2015) In vivo optical elastography: Stress and strain imaging of human skin lesions

Villiger, M., Lorenser, D., Quirk, B.C., Kirk, R.W., Lippok, N., Bouma, B.E., McLaughlin, R.A. and Sampson, David (2015) Polarization sensitive OCT with needle probes

Chin, L., Curatolo, A., Wijesinghe, P., Kennedy, K.M., McLaughlin, R.A., Kennedy, B.F. and Sampson, David (2015) Sensitivity and resolution in optical coherence micro-elastography

Chin, L., Yang, X., McLaughlin, R.A., Noble, P.B. and Sampson, David (2013) Birefringence imaging for optical sensing of tissue damage

McLaughlin, R.A., Lorenser, D. and Sampson, David (2013) Fiber-optic needle probes: Applications in deep tissue Imaging

Kennedy, K.M., Kennedy, B.F., McLaughlin, R.A., Ford, C., Bush, M.B. and Sampson, David (2013) Measuring elastic contrast in tissue using OCT needle probes

Kennedy, B.F., Kennedy, K.M., Ford, C., McLaughlin, R.A., Bush, M.B. and Sampson, D.D. (2012) Optical coherence elastography: Strain imaging in tissue using optical coherence tomography

Kennedy, K.M., Kennedy, B.F., McLaughlin, R.A. and Sampson, D.D. (2012) A new method of optical biopsy: Demonstration of mechanical contrast in deep tissue using an optical coherence elastography needle probe

Kirk, R.W., McLaughlin, R.A., Quirk, B.C., Curatolo, A. and Sampson, D.D. (2011) 3D visualization of tissue microstructures using optical coherence tomography needle probes

Yang, X., McLaughlin, R.A., Lorenser, D., Kirk, R.W., Noble, P.B. and Sampson, D.D. (2011) In situ 3D imaging of alveoli with a 30 gauge side-facing optical needle probe

Sampson, D.D., Quirk, B.C., Curatolo, A., Scolaro, L., Kirk, R.W., Lorenser, D., Pillai, R.S. and McLaughlin, R.A. (2011) Microscope-in-a-needle technology for deep-tissue 3D imaging

Liew, Y.M., McLaughlin, R.A., Curatolo, A. and Sampson, D.D. (2010) Assessment and correction of imaging artifacts in skin imaging using fibre-based optical coherence tomography

McLaughlin, R.A., Williamson, J.P., Curatolo, A., Baker, V.A., Hillman, D.R., Eastwood, P.R. and Sampson, David (2009) In vivo 4D imaging of the human lower airway using anatomical optical coherence tomography

Armstrong, J.J., Becker, S., McLaughlin, R.A., Leigh, M.S., Williamson, J., Walsh, J.H., Hillman, D.R., Eastwood, P.R. and Sampson, David (2008) Anatomical optical coherence tomography: A safe and effective tool for quantitative long-term monitoring of upper airway size and shape

McLaughlin, R.A., Scolaro, L., Klyen, B.R., Hamza, S., Robbins, P., Saunders, C. and Sampson, David (2008) Can normal lymph node architecture be characterised by optical coherence tomography?

McLaughlin, R.A., Armstrong, J.J., Becker, S., Walsh, J.H., Kirkness, J., Jain, A., Leigh, M.S., Williamson, J., Hillman, D.R., Eastwood, P.R. and Sampson, David (2008) Respiratory gating of endoscopic OCT images of the upper airway

Other

McLaughlin, R.A., Scolaro, L., Robbins, P., Saunders, C., Jacques, S.L. and Sampson, David (2009) Mapping tissue optical attenuation to identify cancer using optical coherence tomography .

This list was generated on Fri Feb 21 04:26:08 2020 UTC.

Information about this web site

© The University of Surrey, Guildford, Surrey, GU2 7XH, United Kingdom.
+44 (0)1483 300800