Evaluation of a single-channel nasal pressure device to assess obstructive sleep apnea risk in laboratory and home environments

Crowley, K.E., Rajaratnam, S.M.W., Shea, S.A., Epstein, L.J., Czeisler, C.A. and Lockley, S.W. (2013) Evaluation of a single-channel nasal pressure device to assess obstructive sleep apnea risk in laboratory and home environments Journal of Clinical Sleep Medicine, 9 (2). pp. 109-116.

Full text not available from this repository.

Abstract

Study Objectives: To evaluate the sensitivity and specificity of a portable single-channel (intra-nasal pressure) sleep apnea device (ApneaLink) in both the laboratory and at home for assessment of sleep apnea risk in comparison with standard polysomnography (PSG). Methods: Fifty-five participants underwent simultaneous recordings of standard PSG and ApneaLink in the laboratory. Of these, 38 participants also used the ApneaLink device in their own homes for one night. PSG respiratory events were scored using standard criteria. Intra-nasal pressure signals were analyzed using the ApneaLink automated computerized algorithm provided to yield estimates of airflow for detection of apneas and hypopneas. Apnea-hypopnea indices (AHI) were compared. Results: There was high sensitivity and specificity for the ApneaLink AHI when compared to simultaneous PSG at comparable AHI levels (AHI � 15 events/h; sensitivity 100%, specificity 92%; positive and negative predictive values 70% and 100%, respectively). Home-measured ApneaLink AHI sensitivity and specificity were also reliable when compared with PSG (AHI � 5, 81% and 77%, respectively; AHI � 15, 67% and 91%), and improved slightly when two nights' data were used (AHI � 5, 88% and 85%; AHI � 15, 67% and 93%). Conclusions: The ApneaLink demonstrated good sensitivity and specificity in quantifying AHI when compared to PSG in a population with and without confirmed OSA. This simple, easyto-use device may be useful in de novo large-scale occupational or underserved community OSA diagnostic programs to identify those with unambiguous disease who need immediate treatment or indicate those who may be at increased risk of OSA.

Item Type: Article
Authors :
NameEmailORCID
Crowley, K.E.
Rajaratnam, S.M.W.
Shea, S.A.
Epstein, L.J.
Czeisler, C.A.
Lockley, S.W.s.lockley@surrey.ac.uk
Date : 2013
DOI : 10.5664/jcsm.2400
Uncontrolled Keywords : AHI, ApneaLink, Home monitoring, Obstructive sleep apnea, accuracy, adult, algorithm, apnea hypopnea index, article, female, home environment, home monitoring, human, intermethod comparison, laboratory, major clinical study, male, nose, nose airflow, polysomnography, portable equipment, predictive value, pressure, risk assessment, sensitivity and specificity, single channel sleep apnea device, sleep disordered breathing, Actigraphy, Adult, Cross-Sectional Studies, Equipment Design, Equipment Safety, Female, Home Nursing, Humans, Laboratories, Male, Middle Aged, Monitoring, Ambulatory, Monitoring, Physiologic, Polysomnography, Rhinomanometry, ROC Curve, Sensitivity and Specificity, Severity of Illness Index, Sleep Apnea, Obstructive
Depositing User : Clive Harris
Date Deposited : 17 Jun 2020 01:29
Last Modified : 17 Jun 2020 01:29
URI: http://epubs.surrey.ac.uk/id/eprint/857890

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year


Information about this web site

© The University of Surrey, Guildford, Surrey, GU2 7XH, United Kingdom.
+44 (0)1483 300800