Bassinet, C., Woda, C., Bortolin, E., Monaca, S. Della, Fattibene, P., Quattrini, M., Bulanek, B., Ekendahl, D., Burbidge, C.I, Cauwels, V. , Koroukla, E., Geber-Bergstrand, T., Mrozik, A., Marczewska, B., Bilski, P., Sholom, S., McKeever, S.W.S, Smith, Richard, Veronese, I., Galli, A., Panzeri, L. and Martini, M. (2014) Retrospective radiation dosimetry using OSL of electronic components: Results of an inter-laboratory comparison Radiation Measurements, 71. pp. 475-479.

Full text not available from this repository.

Abstract

In the framework of the EU-FP7 MULTIBIODOSE project, two protocols using OSL of resistors removed from the circuit board of mobile phones were developed with the aim to use the resistors as fortuitous dosimeters in the event of a large scale radiological accident. This paper presents the results of an inter-laboratory comparison carried out under the umbrella of EURADOS. The two aims of this exercise were the validation of the MULTIBIODOSE protocols by a large number of laboratories and the dissemination of the method with the objective of preparing the basis for a network that could increase Europe's response capacity in the case of a mass casualty radiological emergency. Twelve institutes from eleven European countries and one institute from the USA, with various degrees of expertise in OSL dosimetry, took part in the OSL inter-laboratory comparison. Generally, a good agreement within uncertainties was observed between estimated and nominal doses.

Item Type: Article
Divisions : Faculty of Engineering and Physical Sciences > Physics
Authors :
NameEmailORCID
Bassinet, C.
Woda, C.
Bortolin, E.
Monaca, S. Della
Fattibene, P.
Quattrini, M.
Bulanek, B.
Ekendahl, D.
Burbidge, C.I
Cauwels, V.
Koroukla, E.
Geber-Bergstrand, T.
Mrozik, A.
Marczewska, B.
Bilski, P.
Sholom, S.
McKeever, S.W.S
Smith, Richardr.w.smith@surrey.ac.uk
Veronese, I.
Galli, A.
Panzeri, L.
Martini, M.
Date : 31 March 2014
Funders : European Union’s Seventh Framework Programme
DOI : 10.1016/j.radmeas.2014.03.016
Grant Title : European Union’s Seventh Framework Programme
Copyright Disclaimer : © 2014 Elsevier Ltd. All rights reserved
Uncontrolled Keywords : Retrospective dosimetry; Radiological accident; Emergency dosimeter; OSL; Resistor; Mobile phones
Depositing User : James Marshall
Date Deposited : 12 Mar 2020 16:49
Last Modified : 12 Mar 2020 16:49
URI: http://epubs.surrey.ac.uk/id/eprint/853919

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year


Information about this web site

© The University of Surrey, Guildford, Surrey, GU2 7XH, United Kingdom.
+44 (0)1483 300800