Hydrogen Sulphide and VOC Removal in Biotrickling Filters: Comparison of Data from a Full-scale, Low-emission Unit with Kinetic Models

Beigi, B.H.M., Thorpe, R.B., Ouki, S., Winter, P. and Waalkens, A. (2019) Hydrogen Sulphide and VOC Removal in Biotrickling Filters: Comparison of Data from a Full-scale, Low-emission Unit with Kinetic Models CHEMICAL ENGINEERING SCIENCE, 208, 115033.

[img] Text
Thorpe_Rev_Manuscript.docx - Accepted version Manuscript

Download (48MB)

Abstract

In this paper, data is published on the removal of H2S and VOCs by a Biotrickling Filter (BTF) demonstration plant, namely a SULPHUS™, which was installed by Thames Water in late 2015. These data, along with some data already published by Sempere et al. (2018), were compared to the predictions of a number of existing and novel models for the removal of a single pollutant by a biofilm.

The two widely used models of Ottengraf and van den Over (1983) were found to be inadequate with sum of squares of errors of 11 and 41 mg2m-6 respectively. These models are based on zero-order kinetics in the biofilm which according to the M-M kinetic model, are likely to be inaccurate at low pollutant concentration. The odour control unit was designed to produce low emission levels of less than 1 ppmv of H2S, rendering the zero-order assumption unlikely to be accurate. A model based on first-order kinetics, which also has some support in the literature, was found to be a better, but not a good, fit to the data with a sum of squares of errors of 4.7 mg2m-6. A novel model for the BTF based on M-M kinetics was found to be a good fit to the shape of the data with the lowest sum of squares of errors of 2.5 mg2m-6. This novel M-M model was also identified as the best fit for VOC data from the same unit. Other publications support the M-M approach with a product of saturation constant and Henry’s Law constant of about 50 mg m-3, which is equivalent to an H2S level in the gas phase of about 40 ppmv. Broad agreement was found between the SULPHUS™, experiments and data in the literature for other BTFs destroying H2S under the zero-order regime, at V_max value of about 0.3 g/m3/s. This paper represents an attempt to harmonise a literature that was previously disparate, which has not previously been attempted.

Item Type: Article
Divisions : Faculty of Engineering and Physical Sciences > Chemical and Process Engineering
Authors :
NameEmailORCID
Beigi, B.H.M.
Thorpe, R.B.Rex.Thorpe@surrey.ac.uk
Ouki, S.S.Ouki@surrey.ac.uk
Winter, P.
Waalkens, A.
Date : 23 November 2019
Funders : EPSRC - Engineering and Physical Sciences Research Council
DOI : 10.1016/j.ces.2019.06.012
Copyright Disclaimer : Copyright 2019 Elsevier Ltd. All rights reserved.
Uncontrolled Keywords : Biotrickling filter; Biofiltration; H2S; VOC; Model; Odour
Additional Information : The views expressed in the paper are those of the authors and not necessarily those of Thames Water. The authors gratefully acknowledge the support and funding of Thames Water Ltd, Pure Air Solutions and the EPSRC (grant number EP/G037612, provided via the SEES doctoral training programme based at the University of Surrey Centre for the Environment and Sustainability. They would also like to thank F. Sempere and I. Cranshaw for their support during the SULPHUSTM trials that led this paper.
Depositing User : Diane Maxfield
Date Deposited : 18 Jun 2019 16:15
Last Modified : 14 Jun 2020 02:08
URI: http://epubs.surrey.ac.uk/id/eprint/852045

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year


Information about this web site

© The University of Surrey, Guildford, Surrey, GU2 7XH, United Kingdom.
+44 (0)1483 300800