University of Surrey

Test tubes in the lab Research in the ATI Dance Research

Indoor air quality-induced respiratory symptoms of a hospital staff in Iran.

Veysi, Rahmat, Heibati, Behzad, Jahangiri, Mehdi, Kumar, Prashant, Latif, Mohd Talib and Karimi, Ali (2019) Indoor air quality-induced respiratory symptoms of a hospital staff in Iran. Environmental Monitoring and Assessment, 191 (2).

[img]
Preview
Text
Indoor air quality-induced respiratory symptoms of a hospital staff in Iran.pdf - Accepted version Manuscript

Download (499kB) | Preview
[img] Image (Image 001)
image001 - Supplemental Material

Download (42B)
[img] Image (Image 002)
image002 - Supplemental Material

Download (42B)
[img] Image (Image 003)
image003 - Supplemental Material

Download (42B)

Abstract

The ambient air of hospitals contains a wide range of biological and chemical pollutants. Exposure to these indoor pollutants can be hazardous to the health of hospital staff. This study aims to evaluate the factors affecting indoor air quality and their effect on the respiratory health of staff members in a busy Iranian hospital. We surveyed 226 hospital staff as a case group and 222 office staff as a control group. All the subjects were asked to fill in a standard respiratory questionnaire. Pulmonary function parameters were simultaneously measured via a spirometry test. Environmental measurements of bio-aerosols, particulate matter, and volatile organic compounds in the hospital and offices were conducted. T-tests, chi-square tests, and multivariable logistic regressions were used to analyze the data. The concentration of selected air pollutants measured in the hospital wards was more than those in the administrative wards. Parameters of pulmonary functions were not statistically significant (p > 0.05) between the two groups. However, respiratory symptoms such as coughs, phlegm, phlegmatic coughs, and wheezing were more prevalent among the hospital staff. Laboratory staff members were more at risk of respiratory symptoms compared to other occupational groups in the hospital. The prevalence of sputum among nurses was significant, and the odds ratio for the presence of phlegm among nurses was 4.61 times greater than office staff (p = 0.002). The accumulation of indoor pollutants in the hospital environment revealed the failure of hospital ventilation systems. Hence, the design and implementation of an improved ventilation system in the studied hospital is recommended.

Item Type: Article
Divisions : Faculty of Engineering and Physical Sciences > Civil and Environmental Engineering
Authors :
NameEmailORCID
Veysi, Rahmat
Heibati, Behzad
Jahangiri, Mehdi
Kumar, PrashantP.Kumar@surrey.ac.uk
Latif, Mohd Talib
Karimi, Ali
Date : 5 January 2019
DOI : 10.1007/s10661-018-7182-5
Copyright Disclaimer : © Springer Nature Switzerland AG 2019
Uncontrolled Keywords : Hospital; Pulmonary function; Respiratory disease
Depositing User : Clive Harris
Date Deposited : 15 Jan 2019 11:34
Last Modified : 06 Jan 2020 02:08
URI: http://epubs.surrey.ac.uk/id/eprint/850142