University of Surrey

Test tubes in the lab Research in the ATI Dance Research

Calorimetric studies of metal beta-diketonates.

Schulz, Ronald Arthur. (1970) Calorimetric studies of metal beta-diketonates. Doctoral thesis, University of Surrey (United Kingdom)..

[img]
Preview
Text
10804472.pdf
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (3MB) | Preview

Abstract

Heats of solution at 25°C. for six trivalent metal beta-diketonates in benzene, acetone and chloroform, have been measured calorimetrically. These results show that the solution process is only slightly affected by changing the metal complex over the range of tris 2,4-pentanedione chelates, Macac[3] (M = Al, Cr, Mn, Fe, Co), including the gamma-substituted tris (3:methyl-2,4-pentanediono)aluminium(III), but that significant differences exist between solvents. On this basis, conclusions have been drawn regarding the heats of sublimation of the complexes, and tentative suggestions have been put forward regarding possible solvent interaction phenomena. In chloroform solutions, specific interaction involving two molecules of solvent held by hydrogen bonds has been postulated. Thermochemical measurements were carried out on a recording solution calorimeter, developed from a well-tested isothermal jacket design, using a 100 ml glass reaction vessel. The instrument incorporates a direct reading temperature sensing element made up of two chromel-constantan thermocouples connected in parallel. The thermostatically controlled water bath (+/- 0.001°C.) which provides environmental control for the isothermal jacket, has been utilised to stabilise all the temperature sensitive components of the thermocouple circuit, except the sensing junctions, which are housed in a re-entrant tube on the reaction vessel. The thermocouple output is applied to a high gain D.C. amplifier which displays the equivalent temperature (emf.) vs time curve for the calorimeter on a strip-chart recorder. Increased sensitivity has been achieved by using a precision microvolt source in the input circuit, to "back-off" most of the applied signal. Calibration is carried out electrically and reactions involving emf. changes of the order of 1.0 muV have been consistently measured to better than +/- 0.005 muV, i.e. equivalent to a resolution of 1 x 10[-4]°C. or 0.015 joules.

Item Type: Thesis (Doctoral)
Divisions : Theses
Authors :
NameEmailORCID
Schulz, Ronald Arthur.
Date : 1970
Contributors :
ContributionNameEmailORCID
http://www.loc.gov/loc.terms/relators/THS
Additional Information : Thesis (Ph.D.)--University of Surrey (United Kingdom), 1970.
Depositing User : EPrints Services
Date Deposited : 22 Jun 2018 14:26
Last Modified : 06 Nov 2018 16:53
URI: http://epubs.surrey.ac.uk/id/eprint/848002

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year


Information about this web site

© The University of Surrey, Guildford, Surrey, GU2 7XH, United Kingdom.
+44 (0)1483 300800