Commercial glass beads as TLDs in radiotherapy produced by different manufacturers

Jafari, Shakardokht, Bates, Nicholas, Jupp, T, Abdul Sani, S F, Nisbet, Andrew and Bradley, David (2016) Commercial glass beads as TLDs in radiotherapy produced by different manufacturers Radiation Physics and Chemistry, 137. pp181-186.

Full text not available from this repository.

Abstract

While commercial jewellery glass beads offer the basis of novel radiotherapy TL dosimetry (Jafari et al. 2014a,b,c, 2015a,b), detailed study of TL variation is required for the products from various manufacturers. Investigation is made for glass beads from four manufacturers from four countries: China (Rocaille), Japan (Mill Hill), Indonesia (TOHO™) and Czech Republic (Czech). Sample composition was determined using an energy-dispersive X-ray unit coupled to a scanning electron microscope. Values of mass attenuation coefficient, μ/ρ, as a function of photon energy were then calculated for photons of energy 1 keV to 10 MeV, using the National Institute of Standards and Technology XCOM program. Radiation and energy response were determined using X-rays generated at accelerating potentials from 80 kVp to 6 MV (TPR20/10¼0.670). All bead types showed TL to be linear with dose (R240.999). Glow curve dosimetric peaks reached a maximum value at 300 °C for the Toho and 290 °C for the Czech and Mill Hill products but was between 200–250 °C for the Rocaille product. Radiation sensitivity following mass normalisation varied within an order of magnitude; Toho samples showed the greatest and Rocaille the least sensitivity. For the Toho, Czech, Rocaille and Mill Hill samples the energy responses at 80 kVp were 5.0, 4.0, 3.6 and 3.3 times that obtained at 6 MV. All four glass bead types offer potential use as TL dosimeters over doses commonly applied in radiotherapy. Energy response variation was o1% at 6 MV but significant variation was found for photon beam energies covering the kV range; careful characterisation is required if use at this range is intended.

Item Type: Article
Divisions : Faculty of Engineering and Physical Sciences
Faculty of Engineering and Physical Sciences > Physics
Authors :
NameEmailORCID
Jafari, Shakardokhtshakardokht.jafari@surrey.ac.uk
Bates, Nicholasn.bates@surrey.ac.uk
Jupp, T
Abdul Sani, S F
Nisbet, AndrewA.Nisbet@surrey.ac.uk
Bradley, DavidD.A.Bradley@surrey.ac.uk
Date : 2 January 2016
DOI : 10.1016/j.radphyschem.2015.12.025
Copyright Disclaimer : © 2016 Elsevier Ltd. All rights reserved.
Depositing User : Diane Maxfield
Date Deposited : 23 May 2018 15:35
Last Modified : 16 Jan 2019 19:10
URI: http://epubs.surrey.ac.uk/id/eprint/846489

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year


Information about this web site

© The University of Surrey, Guildford, Surrey, GU2 7XH, United Kingdom.
+44 (0)1483 300800