University of Surrey

Test tubes in the lab Research in the ATI Dance Research

Laser Doppler Sensing for Blood Vessel Detection with a Biologically Inspired Steerable Needle

Virdyawan, V, Oldfield, Matthew and Rodriguez y Baena, F (2018) Laser Doppler Sensing for Blood Vessel Detection with a Biologically Inspired Steerable Needle Bioinspiration & Biomimetics, 13 (2), 026009.

[img] Text
main1.pdf - Accepted version Manuscript
Restricted to Repository staff only until 16 February 2019.

Download (948kB)

Abstract

Puncturing blood vessels during percutaneous intervention in minimally invasive brain surgery can be a life threatening complication. Embedding a forward looking sensor in a rigid needle has been proposed to tackle this problem but, when using a rigid needle, the procedure needs to be interrupted and the needle extracted if a vessel is detected. As an alternative, we propose a novel optical method to detect a vessel in front of a steerable needle. The needle itself is based on a biomimetic, multi-segment design featuring four hollow working channels. Initially, a laser Doppler flowmetry probe is characterized in a tissue phantom with optical properties mimicking those of human gray matter. Experiments are performed to show that the probe has a 2.1 mm penetration depth and a 1 mm off-axis detection range for a blood vessel phantom with 5 mm s−1 flow velocity. This outcome demonstrates that the probe fulfills the minimum requirements for it to be used in conjunction with our needle. A pair of Doppler probes is then embedded in two of the four working channels of the needle and vessel reconstruction is performed using successive measurements to determine the depth and the off-axis position of the vessel from each laser Doppler probe. The off-axis position from each Doppler probe is then used to generate a 'detection circle' per probe, and vessel orientation is predicted using tangent lines between the two. The vessel reconstruction has a depth root mean square error (RMSE) of 0.3 mm and an RMSE of 15° in the angular prediction, showing real promise for a future clinical application of this detection system.

Item Type: Article
Divisions : Faculty of Engineering and Physical Sciences > Mechanical Engineering Sciences
Authors :
NameEmailORCID
Virdyawan, V
Oldfield, Matthewm.oldfield@surrey.ac.uk
Rodriguez y Baena, F
Date : 16 February 2018
Identification Number : 10.1088/1748-3190/aaa6f4
Copyright Disclaimer : © 2018 IOP Publishing Ltd. This is an author-created, un-copyedited version of an article accepted for publication in Bioinspiration & Biomimetics and available here under a CC BY-NC-ND 3.0 licence. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The definitive publisher authenticated version is available online at http://iopscience.iop.org/article/10.1088/1748-3190/aaa6f4/meta
Uncontrolled Keywords : Laser Doppler, Steerable Needle, Blood Vessel Detection
Depositing User : Melanie Hughes
Date Deposited : 23 Mar 2018 09:32
Last Modified : 23 Mar 2018 09:33
URI: http://epubs.surrey.ac.uk/id/eprint/846071

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year


Information about this web site

© The University of Surrey, Guildford, Surrey, GU2 7XH, United Kingdom.
+44 (0)1483 300800