University of Surrey

Test tubes in the lab Research in the ATI Dance Research

The experimental analysis and computer simulation of bielectrical referencing systems.

Woods, Duncan E. (1994) The experimental analysis and computer simulation of bielectrical referencing systems. Doctoral thesis, University of Surrey (United Kingdom)..

[img]
Preview
Text
10130993.pdf
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (64MB) | Preview

Abstract

The measurement of bioelectric signals, e.g. the electrocardiogram and electromyogram (EMG), from the body is susceptible to noise, artefacts and interference; such as power-line interference. To reduce these effects differential-input amplifiers are commonly used. Rejection is further enhanced by implementing a referencing system into the design, such as connecting a third electrode to circuit common or driving the shields. However, there has been no quantitative study into the relative merits of the different systems. For this reason, an experimental analysis and computer simulation was undertaken. In the experimental tests, a rig and instrumentation system were developed to record the surface isometric EMG from biceps brachii. Published referencing systems were used in the trials and the recorded signals were quantified using repeatable parameters. These were calculated from the frequency domain and included the median frequency and a measure of the spectral power distribution. The results showed a significant reduction in the interference when a third electrode or isolation was used. No further reduction was observed if a more complex circuit, such as a driven referencing system, was used. In the computer simulation, a SPICE computer model of the recording environment was developed. This included the preamplifier and the interference sources from displacement currents induced into the leads and the body. The different referencing systems were incorporated within this basic structure. The results confirmed those from the experimental work and, by comparison to a 1% tolerance criterion, it was concluded that the driven-right leg or the three electrode driven shield isolated systems were superior. It is concluded that referencing significantly affects interference levels on the bioelectric signal. These results may be used to facilitate a standard system to be adopted in bioelectric amplifiers. The implication for this in clinical practice is that it may improve the measurement of bioelectric signals.

Item Type: Thesis (Doctoral)
Divisions : Theses
Authors :
NameEmailORCID
Woods, Duncan E.
Date : 1994
Contributors :
ContributionNameEmailORCID
http://www.loc.gov/loc.terms/relators/THS
Depositing User : EPrints Services
Date Deposited : 09 Nov 2017 12:13
Last Modified : 16 Mar 2018 12:58
URI: http://epubs.surrey.ac.uk/id/eprint/843128