Konstantinidis, AC, Szafraniec, MB, Speller, RD and Olivo, A (2012) The Dexela 2923 CMOS X-ray detector: A flat panel detector based on CMOS active pixel sensors for medical imaging applications Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 689. pp. 12-21.

Full text not available from this repository.

Abstract

Complementary metal-oxide-semiconductors (CMOS) active pixel sensors (APS) have been introduced recently in many scientific applications. This work reports on the performance (in terms of signal and noise transfer) of an X-ray detector that uses a novel CMOS APS which was developed for medical X-ray imaging applications. For a full evaluation of the detector's performance, electro-optical and X-ray characterizations were carried out. The former included measuring read noise, full well capacity and dynamic range. The latter, which included measuring X-ray sensitivity, presampling modulation transfer function (pMTF), noise power spectrum (NPS) and the resulting detective quantum efficiency (DQE), was assessed under three beam qualities (28 kV, 50 kV (RQA3) and 70 kV (RQA5) using W/Al) all in accordance with the IEC standard. The detector features an in-pixel option for switching the full well capacity between two distinct modes, high full well (HFW) and low full well (LFW). Two structured CsI:Tl scintillators of different thickness (a thin one for high resolution and a thicker one for high light efficiency) were optically coupled to the sensor array to optimize the performance of the system for different medical applications. The electro-optical performance evaluation of the sensor results in relatively high read noise (∼360 e -), high full well capacity (∼1.5×10 6 e -) and wide dynamic range (∼73 dB) under HFW mode operation. When the LFW mode is used, the read noise is lower (∼165) at the expense of a reduced full well capacity (∼0.5×10 6 e -) and dynamic range (∼69 dB). The maximum DQE values at low frequencies (i.e. 0.5 lp/mm) are high for both HFW (0.69 for 28 kV, 0.71 for 50 kV and 0.75 for 70 kV) and LFW (0.69 for 28 kV and 0.7 for 50 kV) modes. The X-ray performance of the studied detector compares well to that of other mammography and general radiography systems, obtained under similar experimental conditions. This demonstrates the suitability of the detector for both mammography and general radiography, with the use of appropriate scintillators. The high DQE values obtained under low mammographic exposures (up to 0.65 for 22.3 μGy) matches the demand for high detectability in imaging of the dense breast. © 2012 Elsevier B.V.

Item Type: Article
Authors :
NameEmailORCID
Konstantinidis, ACa.konstantinidis@surrey.ac.ukUNSPECIFIED
Szafraniec, MBUNSPECIFIEDUNSPECIFIED
Speller, RDUNSPECIFIEDUNSPECIFIED
Olivo, AUNSPECIFIEDUNSPECIFIED
Date : 11 October 2012
Identification Number : https://doi.org/10.1016/j.nima.2012.06.024
Depositing User : Symplectic Elements
Date Deposited : 17 May 2017 12:54
Last Modified : 17 May 2017 12:54
URI: http://epubs.surrey.ac.uk/id/eprint/837179

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year


Information about this web site

© The University of Surrey, Guildford, Surrey, GU2 7XH, United Kingdom.
+44 (0)1483 300800