University of Surrey

Test tubes in the lab Research in the ATI Dance Research

On the comparison of three methods of assessing beam quality for broad beam in vitro cell irradiation

Heuskin, AC, Wéra, AC, Riquier, H, Michiels, C, Bulgheroni, A, Jastrzab, M, Caccia, M and Lucas, S (2011) On the comparison of three methods of assessing beam quality for broad beam in vitro cell irradiation Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 269 (24). pp. 3132-3136.

Full text not available from this repository.

Abstract

The interaction of charged particles with living matter has recently attracted increasing interest in the field of biomedical applications such as hadron therapy, radioprotection and space radiation biology. Particle accelerators are particularly useful in this area. In vitro radiobiological studies with a broad beam configuration require beam homogeneity. The goal is to produce a dose distribution given to a cell population that is as close to uniform as possible. In this paper, we compare the results of three devices used to assess the beam quality for broad beam irradiation: a passivated implanted planar silicon (PIPS) particle detector, a position-sensitive solid state detector, which is camera-like, and a solid state nuclear track detector (CR39). The first device is a PIPS detector of 300 μm nominal depletion depth and an entrance window with a thickness of about 500 . It is collimated with a 0.5 mm aperture and mounted in air on an XY moving table as close as possible to the exit window of the beam line. The second device is a CMOS position-sensitive detector (technological process 0.6 μm AMS CUA), 112 × 112 pixels, with 153 × 153 μm2 pixel size. It allows the user to rapidly obtain dose uniformity over a surface of 1 × 1 cm2. During uniformity and dose rate assessment it is placed in air at the PIPS location. For both detectors, beam profile was obtained for various proton fluxes (from ∼5 × 104 to 106 particles cm-2 s -1). Preliminary tests were made with CR39 using 4 MeV He ++ ions. Results are analysed using Poisson distribution and cell hit probability. © 2011 Elsevier B.V. All rights reserved.

Item Type: Article
Authors :
NameEmailORCID
Heuskin, ACUNSPECIFIEDUNSPECIFIED
Wéra, ACUNSPECIFIEDUNSPECIFIED
Riquier, HUNSPECIFIEDUNSPECIFIED
Michiels, CUNSPECIFIEDUNSPECIFIED
Bulgheroni, AUNSPECIFIEDUNSPECIFIED
Jastrzab, MUNSPECIFIEDUNSPECIFIED
Caccia, MUNSPECIFIEDUNSPECIFIED
Lucas, SUNSPECIFIEDUNSPECIFIED
Date : 15 December 2011
Identification Number : https://doi.org/10.1016/j.nimb.2011.04.096
Depositing User : Symplectic Elements
Date Deposited : 17 May 2017 12:42
Last Modified : 17 May 2017 12:42
URI: http://epubs.surrey.ac.uk/id/eprint/836403

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year


Information about this web site

© The University of Surrey, Guildford, Surrey, GU2 7XH, United Kingdom.