University of Surrey

Test tubes in the lab Research in the ATI Dance Research

Hyperspectral x-ray imaging for scatter removal in mammography.

Green, Faith H. (2016) Hyperspectral x-ray imaging for scatter removal in mammography. Doctoral thesis, University of Surrey.

[img]
Preview
Text
FaithGreenThesis-withcorrections.pdf - Version of Record
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (4MB) | Preview
[img]
Preview
Text
Author_Deposit_Agreement.pdf
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (165kB) | Preview

Abstract

The purpose of this study is to investigate the use of hyperspectral X-ray imaging i.e, an imaging modality where spectral information on detected X-rays is available, for the removal of scatter in mammography. Features that suggest the presence of cancer are often low in contrast or small in size and therefore a good image quality is required in order to locate them. Current mammography systems use an anti-scatter grid to remove scatter from the image. However, this device also absorbs a proportion of the primary beam and therefore a rise in the dose is required in order to compensate for the loss in statistics. Two alternative methods of scatter removal were investigated in this study. Compton scattered X-rays lose energy in the scattering process and therefore appear at a lower energy in the detected spectrum. Imaging using a monochromatic X-ray beam and a spectroscopic detector means that these lower energy scattered X-rays can be removed from the image through spectral windowing. An alternative method of removing scatter is to simulate the scatter using Monte Carlo modelling. Once a scatter spectrum has been obtained using an input spectrum similar to the experimental spectrum it can be subtracted from the detected spectrum, creating a scatter-free image.This work presents imaging work carried out with a pixellated spectroscopic CdTe detector. A first approach involved the use of a mosaic crystal monochromator producing a quasimonochromatic spectrum from which the scattered component can be removed. The second approach involved the subtraction of the scattered spectrum, as obtained from Monte-Carlo modelling, from a full polychromatic spectrum. Both approaches were tested on a customdesigned low contrast test object. Results showed that in the monochromatic approach scatter removal gave a 40% increase in contrast. It was also found that removing scatter using a simulated scatter spectrum and a polychromatic beam produced a contrast improvement of around 15% when compared to full spectrum imaging.

Item Type: Thesis (Doctoral)
Subjects : Medical Physics
Divisions : Theses
Authors :
AuthorsEmailORCID
Green, Faith H.faith_hannah_green@yahoo.co.ukUNSPECIFIED
Date : 29 February 2016
Funders : EPSRC
Contributors :
ContributionNameEmailORCID
Thesis supervisorPani, Silvias.pani@surrey.ac.ukUNSPECIFIED
Depositing User : Faith Green
Date Deposited : 01 Mar 2016 11:34
Last Modified : 01 Mar 2016 11:34
URI: http://epubs.surrey.ac.uk/id/eprint/809905

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year


Information about this web site

© The University of Surrey, Guildford, Surrey, GU2 7XH, United Kingdom.
+44 (0)1483 300800