Left Anterior Descending Coronary Artery (LAD) Doses from Breast Radiotherapy: is Prone Treatment Beneficial?

Kirby, AM, Evans, PM, Haviland, J and Yarnold, JR (2009) Left Anterior Descending Coronary Artery (LAD) Doses from Breast Radiotherapy: is Prone Treatment Beneficial? In: UKRO 2009, 2009-04-06 - 2009-04-08, Cardiff, UK.

Available under License : See the attached licence file.

Download (8kB)
PDF (licence)

Download (33kB)


Breast radiotherapy increases risks of late cardiovascular mortality/morbidity. LAD irradiation is implicated in pathogenesis, but the effects of prone positioning on its dosimetry are unknown. We compared LAD and heart doses from whole (WBI) and partial (PBI) breast radiotherapy planned prone and supine. Methods: Thirty-nine (14 left-breast-affected) patients had titanium clips placed in excision cavity walls at breast-conservation surgery. Each underwent standard supine CT scanning before repositioning and re-imaging prone on an in-house platform with an aperture through which index breast falls. Partial-breast (PB) CTV was defined as tumour bed (clips/architectural distortion) plus 15 mm margin. WBclinical target volume (CTV) was defined using radio-opaque wire marking clinically palpable breast tissue. Heart and LAD were outlined. Conventional tangential-field PBI and WBI plans and dosevolume histograms were produced for each position (total: 156 plans). Mean heart/LAD, and maximum LAD doses were compared. Results: In left-breast-affected patients, mean (SD) LADmean doses were 11.5 (8.4) Gy (supineWB), 12.1 (7.4) Gy (proneWB), 1.7 (1.6) Gy (supinePB), and 3.2 (3.0) Gy (pronePB). Mean (SD) LADmax doses were 47.5 (5.7) Gy (supineWB), 47.4 (3.7) Gy (proneWB), 22.8 (19.3) Gy (supinePB) and 32.1 (17.1) Gy (pronePB). Prone positioning improved heart and LAD doses in 6/ 14 WBI (mean improvement in LADmean ¼ 12.0 Gy) and 3/14 PBI cases (mean improvement in LADmax ¼ 25.3 Gy), but worsened doses in 7/14 WBI (mean increase in LADmean¼ 9.8 Gy) and 8/14 PBI (mean increase in LADmax¼ 24.7 Gy) cases. Breast volume O1000 cm3 correlated with a benefit of prone treatment (P ¼ 0.02). Heart and LAD parameters agreed on the best plan in 24/28 instances. PBI reduced heart and LAD doses in 100% of patients compared to WBI. Conclusions: LAD doses from WBI are significant. Prone positioning is likely to improve heart and LAD dosimetry in women with breast volumes O1000 cm3 (RE cup), but to increase heart/LAD doses in women with breast volumes !1000 cm3. PBI universally improves cardiac dosimetry compared to WBI and all eligible women should be offered participation in PBI trials where available.

Item Type: Conference or Workshop Item (Conference Paper)
Divisions : Faculty of Engineering and Physical Sciences > Electronic Engineering > Centre for Vision Speech and Signal Processing
Authors :
Date : April 2009
Identification Number : 10.1016/j.clon.2009.01.001
Contributors :
Related URLs :
Additional Information : NOTICE: this is the author’s version of a work that was accepted for publication in CLINICAL ONCOLOGY. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in CLINICAL ONCOLOGY, 21(3), April 2009, DOI 10.1016/j.clon.2009.01.001.
Depositing User : Symplectic Elements
Date Deposited : 14 Dec 2012 14:56
Last Modified : 23 Sep 2013 19:53

Actions (login required)

View Item View Item


Downloads per month over past year

Information about this web site

© The University of Surrey, Guildford, Surrey, GU2 7XH, United Kingdom.
+44 (0)1483 300800