Schirru, F, Lohstroh, A, Sellin, J, Nara Singh, S, Scruton, L, Bentley, A, Fox, P, Banu, A, McCleskey, M, Roeder, T, Simmons, E, Alharbi, A, Trache, L, Freer, M, Parker, D and Banu, A (2012) Development of large area polycrystalline diamond detectors for fast timing application of high-energy heavy-ion beams Journal of Instrumentation, 7 (5). ISSN 1748-0221

[img]
Preview
PDF (licence)
SRI_deposit_agreement.pdf

Download (32Kb)
[img]
Preview
PDF
Lohstroh_development.pdf
Available under License : See the attached licence file.

Download (654Kb)

Abstract

We have studied the effects of electrode fabrication and detector capacitance on the time resolution of large area electronic grade polycrystalline chemical vapour deposited diamond sensors that are suitable for time of flight measurements of heavy ions at relativistic velocities. Sensors were prepared both in house, with Al or Au metal contacts, and commercially fabricated with Au/diamond-like carbon contacts. He, Ar and a mixture of Ne and O beams at 16.3, 33.5 and 21-23 MeV/u, respectively were used on these devices whilst arranged in transmission geometry. Signal processing only began over one meter away from the sensors. The present approach, where we have large-area/large capacitance multi-strip detectors with processing electronics at some distance from the target, is compatible with anticipated space limitations in particle- identification and tracking setups at existing and planned nuclear fragmentation facilities. In a systematic study under these conditions, we demonstrate that the time resolution is limited by detector capacitance and energy deposition in the sensors. An intrinsic time resolution σ = (44±5) ps was achieved for a diamond detector of ∼ 14 pF capacitance. We conclude that, once further refinements are made, a large area time of flight detection system using polycrystalline diamond detectors would be able to provide time resolutions better than 40 ps, approaching the requirement for particle-identification in relativistic fragmentation experiments, such as those at the facility for antiproton and ion research, FAIR. © 2012 IOP Publishing Ltd and Sissa Medialab srl.

Item Type: Article
Additional Information: Published by IOP Publishing Ltd for Sissa Medialab. Copyright 2012 Institute of Physics and Sissa Medialab. This is the author's accepted manuscript.
Divisions: Faculty of Engineering and Physical Sciences > Physics
Depositing User: Symplectic Elements
Date Deposited: 26 Jul 2012 13:28
Last Modified: 23 Sep 2013 19:33
URI: http://epubs.surrey.ac.uk/id/eprint/712259

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year


Information about this web site

© The University of Surrey, Guildford, Surrey, GU2 7XH, United Kingdom.
+44 (0)1483 300800